Confirm the mains supply
Record the project input voltage, frequency and whether the supply is stable across the installation site.
Compare LIAM indoor and outdoor LED drivers by output voltage, power range, input voltage and dimming options. Start with the project environment, then narrow the list by the technical requirements that matter most.
Start with the project
Select the situation that best matches the lighting project. The comparison table will narrow to the most relevant series.
Technical comparison
Filter by installation environment, output voltage, power range and dimming requirement. Product pages provide the detailed model options.
| Series & type | Best fit | Output voltage | Power range | Input voltage | Dimming & control |
|---|---|---|---|---|---|
| IndoorZUN Series
Mesh heat-dissipation housing;Low temperature;Semi-potted series
|
Interior lighting and home decoration | 24V | 60-400 W | 180-265 V AC | Paddle dimming |
| IndoorYUO7 Series
Semi-potted series;soft-start function
|
Interior lighting for home and commercial projects | 24V | 60-400 W | 180-265 V AC | Paddle dimming |
| IndoorSUO7 Qianyuan 2nd Generation
Precision potting with soft-start function;With a display screen;USB Type-C female port
|
Interior projects requiring a protected construction | 24V | 100-400 W | 180-265 V AC | Paddle dimming |
| IndoorZHENPIN 3rd Generation Auto-Sensing
Partial potting with display;Push-in lever terminal block
|
LED strips, showrooms and corridor accent lighting | 12V / 24V | 60-400 W | 180-265 V AC | Paddle dimming;auto 12 V / 24 V sensing |
| IndoorLight Series
Copper transformer for stable daily operation;Semi-potted series;Cost-Effective;Popular Choice
|
Interior lighting and home decoration | 24V | 60-400 W | 110-265 V AC | No dimming |
| IndoorSUO7 Series
USB Type-C female port;Semi-potted series
|
Interior lighting and home decoration | 24V | 60-400 W | 180-265 V AC | Paddle dimming |
| IndoorLS Series
12 V, 24 V and 48 V options
|
Flexible interior systems with multiple low-voltage options | 12V / 24V / 48V | 36-400 W | 110-265 V AC | No dimming |
| IndoorRayling Series
Designed for controllable lighting;Semi-potted series
|
Interior lighting where smoother control is required | 24V | 60-400 W | 180-265 V AC | Smart dimming; soft-start |
| IndoorZHENPIN 2nd Generation
Push-in lever terminal block;Semi-potted series
|
Interior projects with 12 V or 24 V lighting loads | 12V / 24V | 60-400 W | 180-265 V AC | Paddle dimming |
| IndoorYUO7 First Generation
First-generation YUO7 platform;Semi-potted series
|
Interior lighting and home decoration | 24V | 60-400 W | 180-265 V AC | Paddle dimming |
| IndoorXingYang Series
Straightforward interior power supply
|
Interior lighting with 12 V or 24 V output | 12V / 24V | 60-400 W | 180-265 V AC | No dimming |
| IndoorLS Series Upgraded
Upgraded LS platform;Porous metal housing
|
Interior lighting projects needing wide input voltage | 24V | 60-400 W | 110-265 V AC | No dimming |
| IndoorValue-Priced Series
Ultra-thin honeycomb structure design
|
interior lighting projects | 24V | 60-300 W | 180-265 V AC | No dimming |
| IndoorMagnetic Lamp Series
48 V magnetic lighting system
|
Residential, office, retail and gallery magnetic lighting | 48V | 100-300 W | 180-265 V AC | No dimming |
| IndoorUltra-Thin & Slim Series
Compact format for concealed installation
|
Advertising, display, mall and transit light boxes | 12V / 24V | 24-100 W | 110-265 V AC | No dimming |
| OutdoorHigh-End Rainproof Model
Rainproof; IP43
|
Outdoor lighting and signage projects needing higher power | 24V | 200-1000 W | 180-265 V AC | |
| OutdoorRainproof Semi-Potted Series
Semi-potted rainproof construction
|
Outdoor projects requiring a 400 W rainproof power supply | 12V / 24V | 400 W | 180-265 V AC | No dimming |
| OutdoorEngineering Shield IP67 Series
IP67, fully sealed resin-potted design
|
Landscape lighting, pool surroundings and exposed outdoor areas | 24V | 60-400 W | 180-265 V AC | No dimming |
Final availability, output current, installation limits and dimming compatibility depend on the exact model and latest technical datasheet. Confirm these details with LIAM before ordering.
Six-step selection guide
Use these checks to prepare a clear selection brief and reduce the risk of a voltage, power or installation mismatch.
Record the project input voltage, frequency and whether the supply is stable across the installation site.
Use the LED load voltage as the first filter: 12 V, 24 V or 48 V. The driver output and lighting load must match.
Add the rated wattage of all connected LED loads. Allow suitable headroom for start-up, voltage drop and future load adjustment.
Choose indoor, rainproof or IP67 protection based on exposure to weather, moisture, dust and insects.
Check the control method, dimming range and system compatibility before selecting a dimmable model.
Confirm enclosure space, mounting direction, cable entry and heat dissipation with LIAM before ordering.
Outdoor selection focus
Rain, moisture, dust, insects and installation orientation can affect long-term performance. Select the protection level for the complete installation, not only the driver enclosure.
Review the High-End Rainproof and Rainproof Semi-Potted series for exposed outdoor lighting projects that require rain protection.
The Engineering Shield IP67 Series uses a fully sealed, resin-potted structure for landscape and other exposed outdoor applications.
Use suitable cable entries, sealing, drainage and mounting orientation so water cannot collect around connectors or wiring.
Share the mounting position, exposure conditions and control requirement with LIAM before selecting the final model.
Selection FAQ
Five common planning questions for indoor, outdoor and dimmable LED lighting projects.
Prepare the LED load voltage, total load wattage, mains input voltage and frequency, installation environment, dimming or control requirement, ambient conditions and available installation space. Sharing these details with LIAM helps narrow the selection quickly.
Match the power supply output to the rated input of the LED load. 12 V is often used for compact low-voltage systems, 24 V is common for longer runs and higher-power lighting, and 48 V is used for compatible 48 V systems such as magnetic lighting. Never connect a load to a different output voltage unless the load and system are explicitly rated for it.
Add the rated wattage of every connected LED load, then allow suitable headroom for start-up, voltage drop and future adjustments. As a general planning practice, many projects allow around 20-30% headroom, but the final margin should be confirmed against the selected model, load type and installation conditions.
Use the Outdoor filter to review the High-End Rainproof, Rainproof Semi-Potted and Engineering Shield IP67 series. The required protection depends on exposure, mounting position, drainage and how the cable entries and connectors are protected. Confirm the complete installation method before ordering.
Yes. Send LIAM the load voltage, total wattage, mains input, installation environment, control method, dimensions and project quantity. The team can recommend a suitable series and confirm the exact model, options and technical details for the project.
Share the output voltage, total wattage, mains input, installation environment, control method, dimensions and project quantity.